4.2 Power Supply Wiring and Grounding

Philips Screw Terminal with Cover
Philips Screw Terminal without Cover
Safety Cover
Terminal
Chassis Ground
Surge / Chassis
Safety Cover
Screws
Connection
Ground Jumper

Figure 7: M2000 Series Philips Screw Terminal Block

The M2000 Family supports dual redundant power supplies – "Power Supply 1 (PS1)" and "Power
Supply 2 (PS2)". The connections for PS1, PS2 and the fail-safe relay are located on the terminal
block as shown in Figure 7.
The M2000 Family is equipped with a Philips Screw Terminal Block. The Philips Screw Terminal
Block has Philips screws with a compression plate allowing either bare wire connections or
crimped terminal lugs. RuggedCom recommend the use of #6 size ring lugs to ensure secure,
reliable connections under severe shock or vibration. The terminal block has a safety cover which
must be removed via two Phillips screws before connecting any wires. The safety cover must be
re-attached after wiring to ensure personnel safety. Refer to Table 3 below for a description of each
terminal as well as sections 4.2.1 through 4.2.3 for wiring examples.