TROUBLESHOOTING
E-49: Starter Safety Relay (Low) (warning lamp flashes: 48) P0616
Generation condition
Recoverability
Control effected by electronic control unit
Service data
Actuator test
Inspection
Electronic control unit connector
Electrical equipment
E-49: Starter Safety Relay (High) (warning lamp flashes: 48) P0617
Generation condition
Recoverability
Control effected by electronic control unit
Service data
Actuator test
Inspection
Electronic control unit connector
Electrical equipment
13E-36
Safety relay is shorted to power supply circuit.
System recovers if signal becomes with starter switch ON position.
• Continuous energization prevention function suspended.
8F: Starter safety relay
B1: Starter safety relay
14
: Safety relay
#201: Safety relay
Safety relay is short-circuited to ground circuit, or open circuited.
System recovers if signal becomes with starter switch ON position.
Continuous energization prevention function suspended.
8F: Starter safety relay
B1: Starter safety relay
14
: Safety relay
#201: Safety relay