Multi-Use Tester Service Data - Mitsubishi 6M60-TL Service Manual

Table of Contents

Advertisement

4. Multi-Use Tester Service Data

• It is possible to see service data and actuator tests simultaneously.
No.
Item
01
Engine Revolution
02
Reference Injection Quantity
Reference Common Rail
07
Pressure
Actual Common Rail Pres-
09
sure
Difference Common Rail
0B
Pressure
Difference Common Rail
0C
Pressure
1F
EGR Position
Accel Pedal Position (unfil-
22
tered)
23
Accel Pedal Position (filtered)
24
Accel Pedal Sensor Voltage 1
25
Accel Pedal Sensor Voltage 2
26
Boost Pressure
27
Intake Air Temperature
35
Water Temperature
36
Fuel Temperature (inlet)
37
Fuel Temperature
38
Atmospheric Pressure
3C
Vehicle Speed
Data
Inspection condition
.rpm
Racing (engine running)
Starter switch ON
.
%
.
%
Starter switch ON
.
%
Starter switch ON
Engine idling
.
MPa
Engine idling
.
%
Idling
[Actuator test]
.
STEP
A1: EGR 1, A2: EGR 2,
A3: EGR 3
Accelerator pedal not depressed 0%
Accelerator pedal gradually de-
pressed
.
%
Accelerator pedal fully de-
pressed
Accelerator pedal not depressed 0%
Accelerator pedal gradually de-
pressed
.
%
Accelerator pedal fully de-
pressed
Accelerator pedal gradually de-
.
V
pressed from released position
Accelerator pedal gradually de-
.
V
pressed from released position
Starter switch On
(engine stopped)
.
KPa
Press the accelerator pedal
(
.
inHg)
down after starting the engine
°C
.
Engine cold
°F)
(
.
Engine cold
°C
.
Engine in process of warming up Value gradually increases.
°F)
(
.
Engine stopped after warming
up
Engine cold
°C
.
Engine in process of warming up Value gradually increases.
°F)
(
.
Engine stopped after warming
up
Engine cold
°C
.
Engine in process of warming up Value gradually increases.
°F)
(
.
Engine stopped after warming
up
Altitude: 0 m
.
KPa
Altitude: 600 m
(
.
inHg)
.km/h
Vehicle in motion
(
.MPH)
13E
Requirement
Value corresponds to tachometer
indication.
0%
20 to 30%
0%
0 MPa or lower
0% or lower
0%
Value gradually increases.
100%
Value gradually increases.
100%
0.85 to 4.15 V
0.85 to 4.15 V
Equal to atmospheric pressure
Gradual raise
Value corresponds to ambient tem-
perature.
Value corresponds to ambient tem-
perature.
Value gradually decreases.
Value corresponds to ambient tem-
perature.
Value gradually decreases.
Value corresponds to ambient tem-
perature.
Value gradually decreases.
101 KPa (29.8 in.Hg)
95 KPa (28.1 in.Hg)
Value corresponds to speedometer
indication.