Settings Required before Application

1-6

Settings Required before Application

These settings are required only for a Through-beam Sensor Head.
The settings for the auto-scale, reference incident level, and linear output
are required before application.
Perform the settings in the following order:

1-6-1 Auto-scale

1-6-2 Reference Incident Level
1-6-3 Linear Output
The auto-scale function can be used only for a Through-beam Sen-
sor Head.
POINT
1-6-1
Auto-scale
Select either millimeters or a percentage for the unit on the main display,
and select whether the incident level or the intercepted amount is dis-
played.
For the default settings, the incident level is displayed as a percentage.
1. Display Unit
Select a percentage or mm to display the incident level on the
main display.
2. Incident Level or Intercepted Amount
Select the incident level or the intercepted amount to use for the
display and the linear output.
Sensor Head Emitter
To measure the incident level, select -L.
To measure the intercepted amount, select -d.
Incident beam width =
Incident level
Sensing object
Section 1-6
Sensor Head Receiver
Intercepted beam width =
Intercepted amount
15