Settings Required before Application
3. Confirmation
Select both the display unit and either the incident level or the in-
tercepted amount, and then press the ENT Key to confirm the
settings. An example is shown below for measuring the incident
level in millimeters.
ZX-LT005 Sensor Head
Emitter
1-6-2

Reference Incident Level

When the Sensor Head is mounted for the first time, set the reference inci-
dent level after adjusting the optical axis.
Reset the reference incident level whenever the position of the Sensor
Head is changed.
Sensor Head Emitter
Adjust the optical axis in RUN Mode so that none of the laser beam is
intercepted, and then press the DOWN Key (
16
Measurement width: 5 mm
Incident level display
For details, refer to 3-8-1 Auto-scaling and 4-5-13 Auto-
scale Settings.
For details, refer to 3-6-2 Reference Incident Level Setting
Function and 4-3-3 Setting the Reference Incident Level.
Section 1-6
ZX-LT005 Sensor Head
Receiver
Select 5−L, and then
press the ENT Key.
Sensor Head Receiver
Press the DOWN Key on the
Amplifier Unit.
) for 3 seconds or longer.