Through-beam Sensor Heads: FUN Mode Functions
3-8-2

Scaling

Scaling is used to arbitrarily change the display value for the measured
value. The display value for any measured value can be input or changed.
When scaling one point, the display value offset is changed; the display
value range is not changed. When scaling two points, both the range and
offset of display values are changed.
Note: The display values for measured values change when a scaling is set, but
the linear output values will remain unchanged. The relation between
measured values and linear output values is set with the monitor focus
function. To alter the output values, set the monitor focus after setting
scaling.
80
One-point Scaling
Before scaling
0
After scaling
Although the range cannot be changed,
the offset can be changed.
Two-point Scaling
Before scaling
20
After scaling
The range and offset can be changed.
Refer to 4-5-7 Setting Scaling.
Refer to 3-5-8 Monitor Focus Function.