Table 8: Detailed Information For Specific Sensors - Kontron MSP8040 Series User Manual

Table of Contents

Advertisement

Table 8: Detailed information for specific sensors

Sensor
Event/Reading
Name
type code
70h
OEM Kontron
IPMI Info-1
Firmware Info
1
75h
OEM Kontron
IPMI Info-2
Firmware Info
2
77h
Power
OEM Kontron
Good
Power Good
6Fh
Jumper
Standard IPMI
Status
sensor specific
6Fh
Power
Standard IPMI
State
sensor specific
6Fh
POST
Standard IPMI
Value
sensor
specific
Sensor Specific
Sensor Type
offset
C0h
OEM
00h
Kontron
01h
Firmware
02h to 0Eh
Info
0Fh
C0h
OEM
00h
Kontron
01h
Firmware
02h to 0Eh
Info
0Fh
00h
01h
02h
03h
04h
05h
08h
06h
Standard
07h
IPMI
08h
Power
09h
Supply
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
00h
D3h
01h
Kontron
02h
OEM
03h
Jumper
04h
Status
05h
Sensor
06h
D1h
00h
Kontron
01h
OEM
02h
Power state
03h
sensor
04h
C6h
00h to 07h
OEM
Kontron
POST Code
14h
Value
www.kontron.com
Event Trigger
Event Code Assert Trigger
Event Overflow Trigger
Code Assert Line (Binary Encoded)
Unused, Reserved
Event Code Assert Trigger
Unused Trigger
Code Assert File Id (Binary Encoded)
Unused, Reserved
5V
1.05V_SUS
0.75V_SUS
1.25V_SUS
1.5V_SUS
3.3V_SUS
Combined (3.3V_SUS & 1.5V_SUS & 1.25V_SUS & 0.75V_SUS)
12V Slot
Vcore
1.3V_SUS
1.7V_SUS
2.5V_Vpp
VttDdr
VddqDdr
Unused
Unused
Jumper 00 Present ( JP4: 1-2 )
Jumper 01 Present ( JP4: 3-4 )
Jumper 02 Present ( JP4: 5-6 )
Jumper 03 Present ( JP4: 7-8 )
Jumper 04 Present ( JP4: 9-10 )
Jumper 05 Present ( JP4: 11-12 )
Jumper 06 Present ( JP4: 13-14 )
Power ON
Power OFF
Power ON Request
Power OFF Request
Full Reset In Progress
POST code LOW byte value, no event genarated on these
offsets
POST Code Error Event Trigger
Event Data 2: POST Low Nibble
Event Data 3: POST High Nibble
MSP8040 Series User Guide Rev. 1.2
// 30

Advertisement

Table of Contents
loading

Table of Contents