Kontron MSP8020 Series User Manual
Hide thumbs Also See for MSP8020 Series:

Advertisement

Quick Links

USER GUIDE
MSP8020 Series
Doc. Rev. 1.1

Advertisement

Table of Contents
loading

Summary of Contents for Kontron MSP8020 Series

  • Page 1  USER GUIDE MSP8020 Series Doc. Rev. 1.1...
  • Page 2 Kontron products. This document does not entail any guarantee on the part of Kontron with respect to technical processes described in the manual or any product characteristics set out in the manual. Kontron assumes no responsibility or liability for the use of the described product(s), conveys no...
  • Page 3 If you have any difficulties using this user's guide, discover an error, or just want to provide some feedback, please send a message to Kontron. Detail any errors you find. We will correct the errors or problems as soon as possible and post the revised user's guide on our website. Thank you.
  • Page 4: Symbols Used In This Manual

    MSP8020 Series User Guide Rev. 1.1 Symbols Used in this Manual DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 5: Table Of Contents

    MSP8020 Series User Guide Rev. 1.1 Table of Contents Symbols Used in this Manual ..................................4 Table of Contents ....................................... 5 List of Tables ........................................6 List of Figures ........................................6 List of Acronyms ......................................... 6 Electrostatic Discharge ....................................7 Limited Warranty........................................
  • Page 6: List Of Tables

    MSP8020 Series User Guide Rev. 1.1 List of Tables Table 1: PCI Mapping ......................................11 Table 2: Node key components per CPU engine ............................. 12 Table 3: Node features ....................................13 Table 4: Default usernames and passwords of management interfaces ..................18 Table 5: BMC Sensor list ....................................
  • Page 7: Electrostatic Discharge

    It does not cover products which have been modified, altered or repaired by any other party than Kontron or their authorized agents. Furthermore, any product which has been, or is...
  • Page 8: 1/ Product Description

    MSP8020 Series User Guide Rev. 1.1 1/ Product Description 1.1. Product Overview The MSP8020 Node series are processor nodes for the SYMKLOUD MS2900 platform Series. Nine nodes can be installed in each MS29xx and each node has two CPU engines. When used with two Hubs, each CPU engine supports two 1GbE ports.
  • Page 9: Figure 2: Msp802X In Rear Of Chassis

    MSP8020 Series User Guide Rev. 1.1 Figure 2: MSP802x in rear of chassis For information on other SYMKLOUD MS29xx components, refer to the specific component’s user manual. To ensure you have the latest document version or to consult other SYMKLOUD documents, visit Kontron website at http://kontron.com/.
  • Page 10: Block Diagram

    MSP8020 Series User Guide Rev. 1.1 1.2. Block Diagram Figure 3: MSP802x block diagram For a block diagram of the entire MS29xx system, refer to the SYMKLOUD MS29xx Platform User’s Guide www.kontron.com // 10...
  • Page 11: Pci Mapping

    MSP8020 Series User Guide Rev. 1.1 1.3. PCI Mapping Table 1: PCI Mapping Bus:Device Device Component Description Note :Function CPU* 00:00.0 0d04 Host bridge Intel Corporation (rev. 08) 00:01.0 0d01 PCI bridge Intel Corporation (rev. 08) 00:02.0 0d26 VGA compatible Intel Corporation (rev.
  • Page 12: Node Key Components

    MSP8020 Series User Guide Rev. 1.1 1.4. Node Key Components Table 2: Node key components per CPU engine Component Description MSP8020: Intel® Core™ i7-4860EQ GT3, 6 MB cache, 1.8 GHz, quad-core, 47 W, 750-MHz Iris™ Pro graphics 5200 MSP8021: Intel® Core™ i7-4700EQ GT2, 6 MB cache, 2.4-3.4 GHz, quad-core, 47 W, 400-1000 MHz Intel®...
  • Page 13: Node Features

    MSP8020 Series User Guide Rev. 1.1 1.5. Node Features Table 3: Node features Feature Description Remote management IPMI 2.0 KVM/virtual media Comprehensive sensor network and event monitoring  Refer to the MSP802x Sensor List for a list of sensors. Validated OS Ubuntu Server, 64-bit, long-term support release 12.04...
  • Page 14: Node Module Leds And Buttons

    MSP8020 Series User Guide Rev. 1.1 1.6. Node Module LEDs and Buttons Figure 4: MSP802x LEDs and buttons Table 4: LED status description and button behavior LED status State ID (blue) Power (green) Status (amber) Identify command in progress Blinking...
  • Page 15: Network Interfacing

    MSP8020 Series User Guide Rev. 1.1 1.7. Network Interfacing The F1 (fabric 1) port of CPU 1 connects to hub 1, the B2 (base 2) port of CPU 1 connects to hub 2, the F2 port of CPU 2 connects to hub 2, and the B1 port of CPU 2 connects to hub 1 (Figure 5). The KVM functionality of each CPU is on each one’s respective fabric port.
  • Page 16: Management Interfacing

    USB drive or ISO image, to the CPU engine as a remote device. Once mounted, the device appears as a local device. For configuration, refer to the MSP802x KVM Configuration guide on Kontron website under product MS2900 Manuals ...
  • Page 17: Figure 6: Diagram Of Interface Paths With A Management Networking Connection

    <node BMC ip address> -U admin –P admin –I lanplus sol activate 2 (CPU2) The OS specific prompt is displayed, e.g., Login. The Kontron ipmitool package can be downloaded from the Kontron MS2900 web page under Tool:  http://www.kontron.com/products/solutions/cloud-computing-platform- solutions/symkloud-ms2900-web.html Ensure the protocol is enabled for the interface you want to access.
  • Page 18: Table 4: Default Usernames And Passwords Of Management Interfaces

    MSP8020 Series User Guide Rev. 1.1 Figure 7: Diagram of interface paths with a serial console connection The serial port communication parameters are 115200 baud, no parity, 8 data bits and backspace key set to "Ctrl-h". BIOS POST and configuration menu redirection is VT100+. OS console support/configuration is customer specific.
  • Page 19: 2/ Extracting And Inserting A Node Module

    MSP8020 Series User Guide Rev. 1.1 2/ Extracting and Inserting a Node Module 2.1. Extracting a Node Module ESD Sensitive Device! Take all necessary ESD protection measures. Steps in blue apply only to hot swap procedures. Press the power button of the node to be extracted. (The power button should be configured in the operating system so that it performs a clean shutdown when pressed.)
  • Page 20: Inserting A Node Module

    MSP8020 Series User Guide Rev. 1.1 2.2. Inserting a Node Module ESD Sensitive Device! Take all necessary ESD protection measures. Holding the handle, insert a node module. Push it in until the safety lock locks in place. The ID LED becomes steady blue and then turns off during BMC initialization.
  • Page 21: 3/ Software Configurations And Conventions

    MSP8020 Series User Guide Rev. 1.1 3/ Software Configurations and Conventions Before you start configuring node modules, read the following list of mandatory tasks. You can refer to this list to ensure you have performed the basic tasks required for proper system operation. Note that some of these tasks may already have been done.
  • Page 22: 4/ Configuring Node Modules

    MSP8020 Series User Guide Rev. 1.1 4/ Configuring Node Modules 4.1. Node Reset To reset the CPU engines of a node: From the Node CPU serial console Send a break sequence (ctrl-break) From the SMWI Navigate to the target CPU Node Under Power Commands, select Reset.
  • Page 23: Boot Order

    MSP8020 Series User Guide Rev. 1.1 4.2. Boot Order To choose the boot order of one of the CPU engines of a processor node: Perform a node reset (section 4.1) Press F2 when prompted to enter the bios setup menu...
  • Page 24: 5/ Performing Updates

    MSP8020 Series User Guide Rev. 1.1 5/ Performing Updates A ZIP file provided by Kontron contains firmware updates for node components. 5.1. Processor Node Update To update the firmware of the node BMC, BIOS and FPGA: SMWI Computer command prompt To update all updatable firmware of the node Dashboard >...
  • Page 25 MSP8020 Series User Guide Rev. 1.1 PAGE LEFT BLANK INTENTIONALY www.kontron.com // 25...
  • Page 26: 6/ Appendix A - Sensor Lists

    MSP8020 Series User Guide Rev. 1.1 6/ Appendix A – Sensor Lists The following tables contain information on the sensors of the MSP802x. Table 7 provides detailed information on the sensors described in blue in either Table 5 BMC sensor list or Table 6 MMC sensor list.
  • Page 27 MSP8020 Series User Guide Rev. 1.1 Hex ID Sensor Name Sensor Type Code Reading Type Code Description 0x0B Temp DIMM A CPU2 01h (Temperature) 01h (Threshold Based) DIMM A CPU2 Temperature via SPD 0x0C Temp DIMM B CPU1 01h (Temperature)
  • Page 28 MSP8020 Series User Guide Rev. 1.1 Hex ID Sensor Name Sensor Type Code Reading Type Code Description 70h (OEM Kontron Internal Internal Management Controller 0x18 IPMI Info-1 C0h (OEM Firmware Info) Diagnostic) firmware diagnostic 71h (OEM Kontron Internal Internal Management Controller...
  • Page 29: Table 6: Mmc Sensor List

    MSP8020 Series User Guide Rev. 1.1 Table 6: MMC Sensor list Hex ID Sensor Name Sensor Type Code Reading Type Code Description Internal Management Controller 0x00 Bx:IPMI Info-1 (OEM Kontron Internal (OEM Firmware Info) firmware diagnostic Diagnostic) Internal Management Controller...
  • Page 30 MSP8020 Series User Guide Rev. 1.1 Hex ID Sensor Name Sensor Type Code Reading Type Code Description 0x0C Bx:Power Good Actual power good status (Power Supply) (OEM) Power good status event that occur 0x0D Bx:PowerGood Evt (Power Supply) (Digital Discrete)
  • Page 31: Table 7: Detailed Information For Specific Sensors

    MSP8020 Series User Guide Rev. 1.1 Table 7: Detailed information for specific sensors Event/Reading Sensor Name Sensor Type Sensor Specific offset Event Trigger type code IPMI Info-1 Event Code Assert Trigger Bx:IPMI Info-1 OEM Kontron OEM Kontron Event Overflow Trigger...
  • Page 32 MSP8020 Series User Guide Rev. 1.1 Event/Reading Sensor Name Sensor Type Sensor Specific offset Event Trigger type code Full Reset In Progress POST Value 00h to 07h POST code LOW byte value, no event genarated on these offsets Bx:POST Value...
  • Page 33 MSP8020 Series User Guide Rev. 1.1 Event/Reading Sensor Name Sensor Type Sensor Specific offset Event Trigger type code Health Status 00h Status not available in current state Event Data 3: Bx: Health Status (OEM Health Status) (Platform Alert) 01h Healthy...
  • Page 34 Kontron is a listed company. Its shares are traded in the Prime Standard segment of the Frankfurt Stock Exchange and on other exchanges under the symbol “KBC”. For more information, please visit: http://www.kontron.com/...

This manual is also suitable for:

Msp8021Msp8022

Table of Contents