Connect Remotely Using Enlighten

To check status of Enphase equipment, do the following:
1. Log on to Enlighten to view the array. Click Devices.
2. A list of equipment appears including the Envoy(s) and all of the devices that the Envoy has
detected. The column on the far right lists the status of each device.
3. To view status information for the Envoy, click the Envoy serial number.
4. This screen indicates status for web communication, power line communication and device
count.
5. Check the report setting. The Envoy sends regular reports to Enlighten over the Internet
connection. The default reporting mode for the Envoy-S is Standard (high-bandwidth). If the site
uses the Enphase Mobile Connect modem, this setting is locked to Low-Bandwidth. Low
bandwidth mode reports 15-minute interval readings and event data to Enlighten four times a
day. Standard reporting sends five-minute interval data to Enlighten every five minutes during
daylight hours. The Enlighten view is refreshed every 15 minutes.
6. From here you can choose to Check Signal Strength or Rescan for Devices as needed. When
checking signal strength, allow up to 15 minutes for a response.
7. If the text to the right of the Update Software indicates that the Envoy-S requires an update, click
Update Software and follow the prompts.
28
Envoy-S Metered Multiphase Installation and Operation
© 2016 Enphase Energy Inc.
141-00035 Rev 01