Step 5: Manage the cabling

A.
Use cable clips or tie wraps to attach the cable to the racking. Leave no more than 1.8 m (6 ft) between cable
clips or tie wraps.
B.
Dress any excess cabling in loops so that it does not contact the roof. Do not form loops smaller than 12 cm
(4¾ in) in diameter.
WARNING: Tripping hazard. Loose cables can become a tripping hazard. Dress the IQ Cable to minimize this
potential.

Step 6: Connect the microinverters

A.
Connect the microinverter. Listen for a click as the connectors engage.
B.
Cover any unused connector on the IQ Cable with the IQ Sealing Cap. Listen for a click as the connectors
engage.