4.3
Removing the pilot assembly.
Note : Because this appliance is fitted with an atmosphere sensing 'Oxy-Pilot' it is not possible to
replace the thermocouple separately, because the thermocouple position is factory set to a tight
tolerance. Any replacement of parts on the pilot requires a complete new pilot assembly.
4.3.1
Prepare work area (lay down dust sheets etc.)
4.3.2
Remove the glass frame assembly as shown in section 2.2 and put it in
a safe location. Remove burner assembly as per section 4.1
4.3.3
Loosen the pilot nut and remove the two screws retaining the pilot
assembly. Unscrew the thermocouple from the gas valve.
4.3.4
Re-assemble in reverse order and carry out a gas tightness test.
4.4
Replacing the batteries in the handset.
4.4.1
Remove and re-fit the new 1 off 9V PP3 battery by removing the cover
on the back of the handset.
4.5
Replacing the batteries in the fire.
4.5.1
Remove the bottom surround infill.
4.5.2
Locate the battery pack at the bottom L/H/S, lift clear and remove the
rear cover from the battery pack by unscrewing the retaining screw.
4.5.3
Replace batteries and re-assemble in reverse order.
4.6
Removing the control board.
4.6.1
Remove the burner from the combustion chamber as described in
section 4.1 and the controls mounting plate as described in section 4.2
4.6.2
Disconnect the interrupter wires, & wiring loom and then lift the control
board clear. Replace in reverse order and re-code handset to the new
receiver.