Preparation Of The Wall - Flavel Sophia Simline BF Installation, Maintenance & User Instructions

Balanced flue log effect gas fire
Table of Contents

Advertisement

Fig. 5
300mm
2.3

PREPARATION OF THE WALL

2.3.1
The appliance and flue pipes must be installed at right angles to the
mounting wall. The appliance itself should be installed vertically against
a flat wall. Where an uneven wall surface is found, appropriate action
should be taken to ensure that the appliance is not stressed or does not
distort when installed.
2.3.2
Ensure that the floor surface onto which the appliance is mounted onto
is flat. The minimum height from the floor to the centre of the flue is
shown on figure 6 overpage.
Flue Terminal
Cavity
746mm
938mm Including
Firebox Flanges
8
Outer Wall
154mm