Fitting The Terminal Guard - Flavel Sophia Simline BF Installation, Maintenance & User Instructions

Balanced flue log effect gas fire
Table of Contents

Advertisement

Fig. 17
2.11.5
Store the glass frame assembly in a safe place.
2.11.6
Re-assemble in reverse order when re-fitting the glass assembly.
Ensure that the glass assembly is correctly located on the top
flange of the combustion chamber, this can be achieved by putting
your hand onto the top edge of the glass frame inside the
convection air aperture and pushing down firmly to check the
glass frame is correctly located.
DO NOT OPERATE THE FIRE WITHOUT THE GLASS FRAME
ASSEMBLY IN POSITION OR NOT CORRECTLY LOCATED.
2.12

FITTING THE TERMINAL GUARD

2.12.1
With the flue terminal in position, place the terminal guard over the top
of the flue terminal and mark the position of the holes on the outer wall.
2.12.2
Remove the terminal guard and drill the 4 off 6 mm holes.
2.12.3
Insert the raw plugs into the drilled holes, replace the terminal guard
over the top of the flue terminal and attach to the wall using the No.12 x
40mm screws provided with the terminal guard.
NOTE :
In England & Wales, building regulations require that a terminal guard should be
fitted if the terminal could come into contact with people near the building or be
subject to damage. BFM Europe Ltd. also recommend the fitting of a flue terminal
guard where regulations do not demand that it be fitted. A suitable flue terminal
guard is supplied with the appliance.