Fig. 27
2 off L/H Burner
Retaining Screws
4.2.5
Remove the four burner retaining screws as indicated in figure 27 above
4.26
Slide the burner assembly to the right, off the injector and remove the
from the firebox.
4.3
REMOVING THE REMOTE CONTROL VALVE FROM THE FIRE
4.3.1
Disconnect the appliance from the gas supply.
4.3.2
Remove the glass front panel as descibed on page 9, (figure 2).
4.3.3
Remove the coals and fuel-bed matrix. Pull the fire forwards and tilt fire
onto its back to allow access to valve underneath (situated on R/H/S).
4.3.4
Disconnect the pilot pipe, inlet pipe,valve to injector pipe and
thermocouple wires from the valve. Unscrew the two bracket retaing
screws, the bracket can then be removed and the valve slid forward off
the bracket.
4.3.5
Replace in reverse order and carry out a gas tightness test
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
Note : Prior to replacing the oxy-pilot on this product due to suspected
failure of the component, it is advisable to remove all debris that has
collected on the lint guard of the oxy-pilot itself.
32
2 off R/H Burner
Retaining Screws

Advertisement