Maintenance; Removal Of The Burner Assembly; Removal Of The Gas Valve - Flavel Sophia Simline BF Installation, Maintenance & User Instructions

Balanced flue log effect gas fire
Table of Contents

Advertisement

Servicing should be carried out annually by a competent person such as a
GAS SAFE registered engineer. It is a condition of the guarantee scheme
that this is carried out by a competent person i.e a GAS SAFE
registered Engineer in accordance with these servicing notes and that the
themocouple is changed annually as a condition of the guarantee.
The condition of the logs should be checked and if necessary the whole set
should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of
access. After any servicing work a gas tightness check must always be
carried out.
For Diagrams refer to Section 2
4.1
Removing the burner assembly from the fire.
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the glass assembly, remove the ceramic logs and vermiculite.
4.1.3
Unscrew and remove the three screws which retain the
lift clear.
4.1.4
To refit the burner assembly, locate the burner unit and refit the three
screws. Refit the fuel-bed referring to section 3 for the correct log
positions. Re-fit the glass frame assembly.
4.2
Removing the gas control valve
4.2.1
Remove the burner assembly as detailed in section 4.1
4.2.2
Isolate the gas supply at the inlet elbow. Remove the controls mounting
plate which is held in position by nine screws. Lift the controls mounting
plate clear taking care not to damage the wiring to the receiver unit.
4.2.3
Remove the valve retaining screws and pipework and remove the valve.
Re-assemble in reverse order and carry out a gas tightness test.
SECTION 4

MAINTENANCE

32
burner ,then

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsbl**rn

Table of Contents