2.7
SECURING OF FIREBOX TO THE OPENING
2.7.1
There is a choice of methods of fixing the firebox that are provided to
enable the installer to deal with any type of installation. The preferred
method of fixing the appliance is the cable fixing method, which is
described in detail in the following section.
2.7.2
If the standard firebox fixing flange is to be used, the firebox may be
secured using the cable method, but in installations where the cable
method is not suitable, e.g.insufficient space behind the firebox, or
loose masonry, the firebox can be fitted directly to either the front of the
fireplace via the flange with the four off screws provided. The firebox will
require sealing to the fireplace, regardless of the method used.
2.7.3
To secure the fire using the preferred cable method, proceed as follows
below :-
2.7.4
Mark out and drill 4 off No 14 6mm holes in the rear face of the fire
opening in the positions as shown in figure 10 below.
Fig. 10
2.7.5
Fit the wall plugs provided and screw the fixing eyes securely into the
rear of the fire opening. Remove the glass frame and burner assembly
as detailed in section 2.11 / 2.13.
2.7.6
Uncoil the two fire fixing cables and thread one end of the each of the
cables through the ears in the top of the fire box lid, and through each
fixing eye at the top. (Removing the top closure plate may improve
access). Thread both cables through the fixing eye's at the bottom,
then the holes at the bottom of the firebox.
2.7.7
Thread the cables through the rear of the firebox, insert the flue pipe /
terminal through the hole in the rear of the opening and offer the firebox
12