Wrapping; Balecontrol E Control Panel - Welger RP 202 CLASSIC Operating Manual

Table of Contents

Advertisement

2
3
9
6
fig. 70
50

9. Wrapping

The following wrapping modes* can be selected
• manual wrapping (twine and net)
• automatic twine wrapping
• automatic net wrapping
• automatic combined wrapping
(only for MASTER and PROFI)
9.1. "BALERCONTROL E Control Panel"
RP 202 • RP 302 CLASSIC and SPECIAL
RP 220 • RP 320 FARMER
The BALERCONTROL E control panel contains the following
functions and displays. (fig. 70):
No. Component
1
8
2
3
1
4
12 V
5
5
4
7
6
7
1742-43
8
9
1
DLC = Daily Counter
2
LTC = Life Time Counter
Function
Green LED
Correct power supply
Red LED
Set bale density reached
Yellow LED
Automatic
(Flashes when the net clutch is in
operation)
Yellow LED
Automatic twine wrapping selected.
(Flashes when the twine motor is in
operation)
Button
Changes
automatic wrapping (manual: lights [3]
and [4] go out).
Depress for 5 seconds:
bale counter (DLC
Button
Trigger the net wrapping by hand
Button
Trigger the twine wrapping by hand
Display
Top
counter (LTC
Bottom row: daily counter (DLC) can
be reset;
buzzer
Pre-selected bale density reached
(on back side)
WELGER RP 202 • RP 220 • RP 302 • RP 320
net
wrapping
between
manual
resets the
1
) to zero.
row:
non-resetting
2
);
selected.
and
life
time

Hide quick links: