8.8. Setting the bale density
RP 202 • RP 302 CLASSIC / SPECIAL
RP 220 • RP 320 FARMER
There is a lever on the right-hand side of the baler to set the
density.
1. With the side panel open, loosen the wing nut.
2. Shift the pointer to set the desired baling density within the
range between "+" and "-".
3. Finally, screw on the wing nut once again.
fig. 69
RP 220 • RP 320 MASTER / PROFI
(See separate operating manual „BALERCONTROL III with
Graphic Display for RP 220/RP 320")
48