12.9. BALERCONTROL III - Quick check
RP 220 • RP 320 MASTER / PROFI
⇒ Plug in the power supply connector;
• ........ The control panel sounds a bleeps ..........................................................................
• ........ Display lights up .......................................................................................................
• ........ The start-up message appears on the display .........................................................
• ........ Monitoring display appears.......................................................................................
• ........ Does the BALERCONTROL accept commands, e.g. density selection?.................
⇒ Mode: Start SETUP
Check the settings:
• Dialog language.............................................................................................................
• Baler type.......................................................................................................................
• Delay 2.5 or 5 seconds .................................................................................................
⇒ Mode: Start SYSTEMINFO
View hardware and software and note as required......................................................
⇒ Mode: Start DIAGNOSIS (alternatively: AUTO DIAGNOSIS )
• In DIAGNOSIS / SENSOR, activate/deactivate each sensor, i.e. hold metal in front of
sensor and away from sensor; check for function, setting and correct position in the
display;...........................................................................................................................
• In DIAGNOSIS / ANALOG, check the electrical values
Set values: a) unloaded: (0), approx.100 to 160, max. total of 305.............................
• DIAGNOSIS / ACTUATOR, check all actuators for -/- and +/+.....................................
• In DIAGNOSIS / VOLTAGE, check the operating voltage
76
b) at maximum load: approx. 244 (10) 244.............................................
− Voltage drop not greater than 1 - 2 Volts ..................................................
− Voltage under load not less than 11 volts ................................................
Step 1
Step 2
Step 3
Step 4
WELGER RP 202 • RP 220 • RP 302 • RP 320