3 Specifications
Pos: 27 /TD/Leistungsbeschreibung/Technische Daten/testo 330 Technische Daten/Messbereiche_Genauigkeiten testo330 @ 6\mod_1278672896705_79.doc @ 65100 @
3.2.4.
Measuring ranges and resolution
Parameter
O
2
CO
CO, H
COlow
AmbCO
through flue gas
probe
AmbCO with
probe 0632 3331
NO
Draught
ΔP
Temperature
Efficiency net
Flue gas loss
AmbCO2 with
probe 0632 1240
Gas leak testing
with probe
0632 3330
1
above the sensor protection threshold: Resolution 500 ppm (up to max. 30000
ppm)
12
Measuring range Resolution
0...21 Vol.%
0...4000 ppm
1
-comp.
0...8000 ppm
2
0...500 ppm
0...2000 ppm
0...500 ppm
0...3000 ppm
-9.99...40 hPa
0...300 hPa
-40...1200 °C
0...120 %
0...99.9 %
0...1 vol.
0...10000 ppm
0...10000 ppm
CH4 / C3H8
0.1 vol.%
1 ppm
1 ppm
0.1ppm
1 ppm
1 ppm
1 ppm
0.01 hPa
0.1 hPa
0.1°C (-40.0...999.9 °C)
1°C (rest of range)
0.1 %
0.1 %
-
-