Technical Data; Measurement Ranges And Resolution; Other Instrument Data - TESTO 310 II Instruction Manual

Flue gas analyser
Hide thumbs Also See for 310 II:
Table of Contents

Advertisement

1.888.610.7664

11 Technical data

11 Technical data

11.1 Measurement ranges and resolution

Measure-
Measure-
Resolution
ment
ment
parameter
range
O2
0.0 ...
0.1 Vol.%
21.0 Vol.%
CO
0 ...
1 ppm
4000 ppm
COamb
0 ...
1 ppm
4000 ppm
-0.5 hPa ...
Draft
0.01 hPa /
+2 hPa
0.01 InH
ΔP
-10.0 ...
0.1 hPa /
40.0 hPa /
0.1 InH
-4 ...
+16 InH
O
2
Flue gas
0 ... 400 °C
0.1 °C /
/ +32 ...
temperature
0.1 °F
+752 °F
Combustion
-20...100°C/
0,1 °C /
-4 ... 212°F
air
0.1 °F
temperature

11.2 Other instrument data

-20 ... +50 °C / -4 ... +122 °F
Storage and transport
temperature
-5 ... +45 °C / +23 ... +113 °F
Operating temperature
0 ... 80 %RH
Humidity application
range
≤ 2000 m / ≤ 6562 ft
Operating altitude
Protection class
IP40
62
www.calcert.com
15
10
20
5
25
0
30
Accuracy
±0.2 Vol.%
±20 ppm (0 ... 400 ppm)
±5 % of m.v. (401 ...
2000 ppm)
±10 % of m.v. (2001 ...
4000 ppm)
±20 ppm (0...400 ppm)
±5% of m.v. (401...
2000 ppm)
±10% of m.v. (2001...4000
ppm)
± 0.02 hPa / ± 0.01 InH
2
O
or ±5 % of m.v.
2
± 0.5 hPa / ± 0.2 InH
O
2
(0 ... 40 hPa / 0 ... +16
O
2
InH
O)
2
±1 % of m.v. (rest of range)
± 1 °C (0 ... 100 °C) /
± 1.8 °F (+32 ... +212 °F)
± 1.5 % of m.v. (rest of
range)
± 1 °C /
± 1 °F
Response
time t90
@ 22 °C /
72 °F
30 s
60 s
60 s
-
O
-
<50 s
<50 s
sales@calcert.com

Advertisement

Table of Contents
loading

Table of Contents