6.2.14.

Automatic furnaces

With the help of the readout adapter for automatic furnaces
(0554 1206) status data and error messages can be read out of
compatible automatic furnaces, see also documentation on readout
adapter. The range of data which can be read out depends on the
type of the automatic furnace.
Calling up the function:
1. Connect the readout adapter to the instrument (PS2 interface)
and to the automatic furnace (use adapter ring if necessary).
2.
[
[OK].
-
The data are read from the automatic furnace. Depending on
the automatic furnace, the data are updated at the latest every
30 s.
Reading out current status data:
The current data are displayed after a connection has been set up
to the automatic furnace. The following data are displayed with the
help of symbols:
Component
Air controller
Motor
Valve 1
Valve 2
Flame
Ignition
Oil prewarmer
Options
>
[Options]
>
[Options]
>
[Options]
readout adapter are displayed.
]
Measurements
The values are saved in a measuring report or transferred
to a pocket PC / PC, together with the measuring values of
a flue gas measurement.
Status ON
→ Clipboard: Data are saved to the clipboard:
→ Save: The readings are saved in a record.
Adapter
[OK]
Automatic Furnace
Status OFF
Information: Type and version of
6 Using the product
55