Figure 3-14:
24
22
20
18
16
14
A
12
10
8
6
4
2
0
A. Output amplitude (V)
B. Load resistor (Ω)
3.4.4
Wire the Frequency output (externally powered) (Channel D)
Important
Meter installation and wiring should be performed by suitably trained personnel only in accordance
with the applicable code of practice.
Procedure
Wire to the appropriate output terminal and pins.
Figure 3-15:
7
A
8
A. Frequency output
B. 3–30 VDC (maximum)
C. 500 mA current (maximum)
D. Signal device
Quick Installation Guide
Internally powered Frequency output: output amplitude
versus load resistance [24 VDC (Nom) open circuit]
0
2500
Frequency output wiring (externally powered)
5000
7500
B
Installation Manual
10000
B
C
D