Emerson Micro Motion 5700 Installation Manual page 33

Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

December 2014
Figure 3-10:
A
A. Frequency output
B. Channel B or C
C. See
Figure 3-11
D. Counter
Figure 3-11:
24
22
20
18
16
14
A
12
10
A. Output amplitude (V)
B. Load resistor (Ω)
3.4.2
Wire the Frequency output (externally powered) (Channels B/C)
Important
Meter installation and wiring should be performed by suitably trained personnel only in accordance
with the applicable code of practice.
Quick Installation Guide
Frequency output wiring (internally powered)
B
for output amplitude versus load resistance
Internally powered Frequency output: output amplitude
versus load resistance [24 VDC (Nom) open circuit]
8
6
4
2
0
0
250
500
750
B
Installation Manual
C
D
1000
33