Make the Final Connections

After planning the DC and AC connections and mounting the
charger, the last procedures, including installing the DC
terminal rubber boots for drip protection, will finalize the
wiring connections.
NOTE: Not to scale. For illustration purposes only.
L
N
G
DC connections
1.
Negative Cable (main) to charger.
2.
Positive Cable (bank 1*) to charger.
3.
Positive Cable (bank 2) to charger.
4.
Positive Cable (bank 3) to charger.
5.
Positive Cable (bank 1*) to battery.
6.
Positive Cable (bank 2) to battery.
7.
Positive Cable (bank 3) to battery.
8.
Negative Cable (A) to battery terminal (bank 1*).
9.
Negative Cable (A) to DC negative bus (bank 1*).
10. Negative Cable (B) to battery terminal (bank 2).
11. Negative Cable (B) to DC negative bus (bank 2).
12. Negative Cable (C) to battery terminal (bank 3).
13. Negative Cable (C) to DC negative bus (bank 3).
14. Negative Cable (main) to negative bus bar.
15. Ground Cable to DC ground stud.
Important: When installing only a single bank (or one battery) for
Truecharge™ 2 Battery Chargers that have multiple outputs, positive bank
1 must be utilized. Bypassing bank 1 and using any of the other banks
(bank 2 or bank 3) may render the charger to function improperly.
Figure 2-4 Final DC Wiring Connection Order