AC Input Specifications

AC input voltage range
Nominal:
Full:
Automatic derating to 60% output:
Max. AC input current
Power factor at rated load
Frequency
Efficiency – peak
Surge protection
975-1038-01-01
110 | 120 | 230 | 240 VV
100 – 270  VV
80 – 100 VV
19.6 A
≥0.98
45 – 65 Hz
88%
Line-to-neutral surge protector rated at
275 VV

DC Output Specifications

a
Battery types
Number of diode-isolated battery
bank outputs
DC (battery) output voltage range
including dead battery charging
voltage
Maximum equalization voltage
Voltage accuracy (no load)
Nominal battery voltage
Normal operating output range
Maximum DC output current (total)
a
Do not mix battery types. Refer to battery manufacturer specifications for correct battery type.

AC Input Specifications

XPLORE Charger
Flooded, GEL, AGM, 
LFP (lithium iron phosphate), or Custom
6 separated outputs
0 – 16  VZ
16  VZ
14.4 ±0.1 VZ
@ 77 °F (25 °C)
12 VZ
0 – 16 VZ
120 +10% A
55