Group 51: Ext Comm Module

Parameters of this group need to be adjusted when a DDCS option module is installed. Refer to
option module documentation for more information regarding these parameters.
Code Description
5101 FIELDBUSPAR 1
Parameter 1 of communication module in DDCS link. Value reflects the type of connected DDCS option
module.
Table 11 List of module types.
5102 -
FIELDBUSPAR 2 - FIELDBUSPAR 15
5115
Refer to option module documentation for more information on these parameters.
ACS 400 User's Manual
Value
Module type
0
No module connected.
1
NPBA Profibus
2
NMBA Modbus
3
NIBA Interbus-S
4
NCSA CS31 bus
5
NCAN CANopen
6
NDNA DeviceNet
7
NLON LONWORKS
8
NMBP Modbus+
9
Others