Control Output Connections - Baldor VS1SM Installation & Operating Manual

Single phase ac drive
Table of Contents

Advertisement

5.3

Control Output Connections

The Analog and Digital outputs are shown in Figure 5‐4.
1.
Connect an external analog output device to AM terminal and it's reference to CM.
2.
The normally Open and Closed relay outputs can be connected to an external device, terminal 30B
is the common terminal.
3.
A multi-function open collector output can drive a digital load, connect to MO and EXTG.
VS1SM
30A
30B
30C
MO
EXTG
5-4 Control Wiring
Figure 5‐4 Output Connections
Tightening Torque = 3.5 lb-in (0.4Nm)
AM
CM
Relay Output
Digital Output
Analog Output
(0-10VDC)
MN761

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vs1sm80p5Vs1sm81Vs1sm82

Table of Contents