Baldor VS1SM Installation & Operating Manual page 35

Single phase ac drive
Table of Contents

Advertisement

7.2 Function Group1
Parameter #
MN761
Continued
Access
Parameter Name, Value Range, Description and Preset Value
RW
User V/F Frequency 4 (Range: 0-400Hz)
Sets Frequency 4 in User Defined V/F Pattern. See also F38.
Cannot be greater than F21.
Preset Value:
RW
User V/F Volts 4 (Range: 0-100%)
Sets Voltage 4 in User Defined V/F Pattern as a % of ?? See also F37.
Preset Value:
Output Voltage Scale (Range: 40-110%)
RW
Adjusts the output voltage as a percentage of Input Voltage.
Useful for a motor that has a rated voltage less than the line voltage.
Preset Value:
Voltage
100%
70%
RW
Energy Saving Level (Range: 0-30%)
Sets the amount of output voltage decrease when light load is detected.
For fan or pump applications, energy savings can be significant.
Preset Value:
Output voltage
Electronic Thermal (Range: 0=Off, 1=On)
RW
If motor current exceeds F51 for 1 minute the output is turned off and the
motor coasts to stop (Trip).
Preset Value:
Current
1
00
9
5
65
60.00
Parameter is only displayed when F30=2.
100
Parameter is only displayed when F30=2.
100
100% setting
70% setting
Base freq.
0
Current
0
H53 = 1
H53 = 2
Freq
20
60
Freq.
F40
Current
F51
F52
60
Parameter Descriptions 7-7
time