Baldor VS1SM Installation & Operating Manual page 48

Single phase ac drive
Table of Contents

Advertisement

7.4 I/O Group
Continued
Parameter #
7-20 Parameter Descriptions
Access
Parameter Name, Value Range, Description and Preset Value
RW
I Input Minimum Current (Range: 0-20mA)
Sets the minimum current of the I Input.
Preset Value:
RW
Speed Corresponding to I12 (Range: 0-400Hz)
Sets the minimum frequency at minimum I input current as set in I12.
Preset Value:
RW
I Input Maximum Current (Range: 0-20mA)
Sets the maximum current of the I input.
Preset Value:
RW
Speed Corresponding to I14 (Range: 0-400Hz)
Sets the maximum frequency at maximum I input current as set in I14.
Preset Value:
RW
Criteria for Analog Input Signal Loss (Range:
0- Disabled (Does not check the analog input signal loss)
1- Activated when drops below 50% of set value
2- Activated when drops below set value)
Sets the level at which the analog input signal is considered lost.
Preset Value:
Example:
I62=2,
I63=5.0 sec and
I54=11.
4.00
0.00
20.00
60.00
0
Set freq
Freq
MO
R
un
5
sec
MN761