7.4

I/O Group

Parameter #
MN761
Access
Parameter Name, Value Range, Description and Preset Value
RW
Jump Code (Range: 0-63)
Sets the parameter number to jump to within I/O Group.
Allows quick access to a desired parameter.
Preset Value:
RW
Filter Time Constant for V0 Input (Range: 0-9999)
Adjusts the analog voltage input signal by keypad potentiometer.
Preset Value:
RW
V0 Input Minimum Voltage (Range: 0-10V)
Sets the minimum voltage of the V0 input.
Preset Value:
RW
Speed Corresponding to I2 (Range: 0-400Hz)
Sets the output frequency at minimum V0 input voltage set in I2.
Preset Value:
RW
V0 Input Maximum Voltage (Range: 0-10V)
Sets the maximum voltage of the V0 input.
Preset Value:
RW
Speed Corresponding to I4 (Range: 0-400Hz)
Sets the output frequency at maximum V0 input voltage as set in I4.
Preset Value:
RW
Filter Time Constant for V1 (Range: 0-9999)
Sets the responsiveness of V1 Input (0-10V).
Preset Value:
RW
V1 Input Minimum Voltage (Range: 0-10V)
Sets the minimum voltage of the V1 Input.
Preset Value:
RW
Speed Corresponding to I7 (Range: 0-400Hz)
Sets the output frequency at minimum V1 input voltage as set in I7.
Preset Value:
RW
V1 Input Maximum Voltage (Range: 0-10V)
Sets the maximum voltage of the V1 input.
Preset Value:
RW
Speed Corresponding to I9 (Range: 0-400Hz)
Sets the maximum frequency at maximum V1 input voltage as set in I10.
Preset Value:
RW
Filter Time Constant for I Input (Range: 0-9999)
Sets the internal filter constant of the input section for I input.
Preset Value:
1
10
0
0.00
10.00
60.00
10
0
0.00
10.00
60.00
10