Jog Reference - YASKAWA V7 Technical Manual

Hide thumbs Also See for V7:
Table of Contents

Advertisement

5.12 JOG REFERENCE

n032 : Jog Reference
n050 thru n056 : Multi-function Inputs
When jog operation is selected (by external Jog and Run signals), the Drive output will ramp to the
output level set by this parameter.
When an external Jog signal is present, it will override the existing operation mode and the Drive
will ramp to the level set by this parameter.
EXAMPLE:
OPERATION BY REMOTE SIGNAL INPUT (RUN & JOG)
*
RUN
(Term. S1-S7) JOG
FREQ. CMD
n032 JOG
REF.
0
*
RUN
(Term. S1-S7) JOG
FREQ. CMD
n032 JOG
REF.
0
Also see descriptions of MULTI-FUNCTION INPUT TERMINALS, paragraph 5.18.
(Term. S1 - S7)
*
5-13
Factory setting: 6.00 Hz
Range: 0.00 to 400.0 Hz
Data 10 : Jog Selection
Or FWD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V74x

Table of Contents