N080 - YASKAWA V7 Technical Manual

Hide thumbs Also See for V7:
Table of Contents

Advertisement

Table 6-1. Alarm Displays and Corrective Actions - Continued
Alarm Display
Digital
RUN (Green)
Operator
ALARM (Red)
Blinking
Blinking
Blinking
Blinking
Drive
Explanation
Status
CAL (MODBUS
communications waiting)
Correct data has not been
received from the PLC
when the parameter
n003 (operation command
selection) is 2 or
n004 (frequency reference
selection) is 6,
and power is turned ON.
OPE
(Parameter setting
error when the parameter
setting is performed
through the MODBUS
communications)
OPE1: Two or more values
are set for multi-
function input
selection.
(parameters n050 to
n056)
OPE2: Relationship among
V / f parameters is not
correct.
(parameters n011,
n013, n014, n016)
OPE3: Setting value of
electronic thermal
standard current
exceeds 150% of
drive rated current.
Warning
(parameter n036)
only.
OPE4: Upper / lower limit
Fault
of frequency
contacts
reference is reversed.
do not
(parameters n033,
change
n034)
state.
OPE5: (parameters n083 to
n085)
OPE9: Carrier frequency
setting is incorrect.
(parameter n080)
OL 3 (Overtorque
detection)
Motor current exceeded
the preset value in
parameter n098.
SEr (Sequence error)
Drive receives
LOCAL / REMOTE select
command or
communication / control
circuit terminal changing
signals from the multi-
function terminal while the
drive output is ON.
6-2
Causes and
Corrective Actions
Check communication
devices, and transmission
signals.
Check the setting values.
Reduce the load, and
increase the accel / decel
time.
Check the external circuit
(sequence).

Hide quick links: