Appendix 3. CAPACITY & CONTROL METHOD
The factory setting of certain parameters change with drive rating and control method selected. The
following two tables list the parameters and how they change.
Table A3-1. Parameters Related to Drive Capacity
Model
CIMR-V7*U
MV
20P1
A001
20P2
A002
20P4
A003
20P7
A005
21P5
A008
22P2
A011
23P7
A017
25P5
A025
27P5
A033
40P2
B001
40P4
B002
40P7
B003
41P5
B005
42P2
43P7
B009
45P5
B015
47P5
Table A3-2. Parameters Related to Control Method
Parameter
n014
Frequency - Midpoint
n015
Voltage - Midpoint
n016
Frequency - Min.
n017
Voltage - Min.
n097
Overtorque Detection Selection
n104
Torque Compensation Time
n108
Motor Leakage Inductance
n109
Torque Compensation Limit
n111
Slip Compensation Gain
n112
Slip Compensation Time
n113
Slip Compensation Selection During Regeneration
n139
Energy Saving Selection
RELATED PARAMETERS
n036
n105
n106
0.6
1.7
2.5
1.1
3.4
2.6
1.9
4.2
2.9
3.3
6.5
2.5
6.2
11.1
2.6
8.5
11.8
2.9
14.1
19.0
3.3
19.6
28.8
1.5
26.6
43.9
1.3
0.6
3.4
2.5
1.0
4.0
2.7
1.6
6.1
2.6
3.1
11.0
2.5
4.2
11.7
3.0
7.0
19.3
3.2
9.8
28.8
1.5
13.3
43.9
1.3
Description
A3-1
n107
n108
n110
17.99
110.4
72
10.28
56.08
73
4.573
42.21
62
2.575
19.07
55
1.233
13.40
45
0.800
9.81
35
0.385
6.34
32
0.199
4.22
26
0.111
2.65
30
41.97
224.3
73
19.08
168.8
63
11.22
80.76
52
5.044
53.25
45
3.244
40.03
35
1.514
24.84
33
0.797
16.87
26
0.443
10.59
30
V/f Control Mode
(n002 = 0)
1.5
12.0 (230V)
24.0 (460V)
1.5
12.0 (230)
24.0 (460)
0.0
0.3
N/A
N/A
0.0
2.0
N/A
0.0
n140
n158
481.7
0
356.9
1
288.2
2
223.7
3
169.4
4
156.8
5
122.9
7
94.8
9
72.7
10
713.8
21
576.4
22
447.4
23
338.8
24
313.6
25
245.8
27
189.5
29
145.4
30
Open Loop Vector
(n002 = 1)
3.0
11.0 (230V)
22.0 (460V)
1.0
4.3 (230)
8.6 (460)
N/A
0.2
See table A3-1
150
1.0
0.2
0.0
N/A

Hide quick links: