N102 - YASKAWA V7 Technical Manual

Hide thumbs Also See for V7:
Table of Contents

Advertisement

PARA-
METER
NAME
n096
Overtorque Detection (OL3)
Overtorque Detection
n097
Selection (OL3)
(Note 5)
Overtorque Detection
n098
Level (OL3)
Overtorque Detection
n099
Delay Time (OL3)
Up/Down Hold
n100
Memory
Speed Search
n101
Deceleration Time
Speed Search Operation

n102

Level
Torque Compensation Gain
n103
(Note 4)
Torque Compensation
n104
Time Constant
Torque Compensation
n105
Iron Loss
n106
Motor Rated Slip (Note 4)
Motor Line-to-line
n107
Resistance
Motor Leakage
n108
Inductance (Note 1)
Torque Compensation
n109
Limit
n110
Motor No-load Current
n111
Slip Compensation Gain (Note 4)
Slip Compensation Primary
n112
Delay Time
Slip Compensation Selection
n113
During Regeneration
Stall Prevention Above Base
n115
Speed During Run
Stall Prevention During Run,
n116
Accel/Decel Time Select
n117
Undertorque Detection
Select (UL3)
Undertorque Detection
n118
Level (UL3)
Undertorque Detection
n119
Time (UL3)
n120
Frequency Reference 9 (Note 4)
n121
Frequency Reference 10 (Note 4)
n122
Frequency Reference 11 (Note 4)
n123
Frequency Reference 12 (Note 4)
n124
Frequency Reference 13 (Note 4)
n125
Frequency Reference 14 (Note 4)
n126
Frequency Reference 15 (Note 4)
n127
Frequency Reference 16 (Note 4)
Table A1-1. Drive Parameters - Continued
SETTING RANGE
(AND UNITS)
0:
Detection Disabled
1:
Detect only at set frequency;
operation continues
2:
Detect only at set frequency;
coast to stop
3:
Detect during all frequency conditions;
operation continues
4:
Detect during all frequency conditions;
coast to stop
0:
Detected by output torque
1:
Detected by output current
30 to 200
0.1 to 10.0
0:
Disabled
1:
Enabled
0.0 to 10.0
0 to 200%
0.0 to 2.5
0.0 to 25.5
0.0 to 6550
0.0 to 20.0
0.000 to 65.50
0.00 to 655.0
0 to 250
0 to 99
0.0 to 2.5
0.0 to 25.5
0:
Disabled
1:
Enabled
0:
Disabled
(level is based on setting of n094)
1:
Enabled
(level at Fmax is n094 x 0.4)
0:
Follows acc/dec #1 (n019, n020)
or acc/dec #2 (n021, n022)
Note: Multi-Function input selectable
1:
Follows acc/dec #2 (n021, n022)
always
0:
Undertorque detection disabled
1:
Detected during constant speed running.
Operation continues after detection
2:
Detected during constant speed running.
Operation stops during detection
3:
Detected during all frequency conditions.
Operation continues
4:
Detected during all frequency conditions.
coast to stop
0 to 200%
Inverter rated current = 100%; if n097 = 0
(detection by torque); motor rated torque
becomes 100%
0.1 to 10.0
0.00 to 400.00
A1-5
SETTING
FACTORY
USER
INCREMENT
SETTING
SETTING
1
0
1
0
1 (%)
160
0.1 (sec)
0.1
1
0
0.1 (sec)
2
1 (%)
150
0.1
1.0
0.1 (sec)
(Note 2)
0.1 (W) or
(Note 1)
1 (W)
0.1 (Hz)
(Note 1)
(Note 1)
0.001 (ohm)
0.01 (mH)
(Note 1)
or 0.1 (mH)
150
1 (%)
1 (%)
(Note 1)
0.1
(Note 2)
0.1 (sec)
(Note 2)
1
0
1
0
1
0
1
0
1(%)
0
0.1
0.1 (sec)
0.00
0.01 (Hz)
0.00
(< 100 Hz)
0.00
or
0.00
0.1 (Hz)
0.00
(>= 100 Hz)
0.00
0.00
0.00
PARA.
REF.
5.20
5.10
5.18
5.18
5.26
2.2, 5.22
5.26
2.2
5.22
5.23
5.34
5.11