Plc Link - Panasonic LP-ABR11 Setup And Operation Manual

Lp-abr10 series code reader
Table of Contents

Advertisement

7.9

PLC Link

Term
Command
IP address and
port number of
IPPLC=xxx.xxx.xxx.xxx:
Destination
nnnn
PLC
PLC Link
PLCMODE=a
Start/Exit
Initial address
PLCDTA=a
Padding
PLCPAD=a
character
SYNC IN by
PLCTRIG=a
trigger area
Trigger area
Moniroting
PLCINTVL=a
time
Wait time of
Trigger area
PLCTIM=a
monitoring time
Endian
PLCMCEND=a
Satus
?PLC
transmission
Description
Set the IP address and port number of Destination PLC
192.168.0.10: 9600 (*)
Start/Stop PLC Link function
a=0; Exit PLC link mode (*)
a=1; Mitsubishi MELSEC Q/L SeriesUDP
MC protocol QnA compatible 3E frame(binary code)
a=2; Mitsubishi MELSEC Q/L Series 232C
MC protocol QnA compatible 3C frame(ASCII code)
a=3; OMRON SYSMAC series UDP
FINS command
a=4; OMRON SYSMAC series 232C
C mode command
a=5; Mitsubishi MELSEC FX series UDP
MC protocol A compatible1E frame(binary code)
a=6; Mitsubishi MELSEC FX series 232C
MC protocol A compatibleC frame(ASCII code)
a=7; KV series UDP
KV command mode
a=8; KEYENCE KV series 232C
KV command mode
Set the initial address
a=0-32767
0(*)
Set the padding character to add when the captured data
digits is odd
a=0 ( NULL[0x00] ) (*)
a=1(blank [0x20])
Set the presence or absence of SYNC IN by PLC using
trigger area
a=0 Enable the SYNC IN by trigger area (*)
a=1 Unable the SYNC IN by trigger area
Set the time interval from the monitoring completion of the
trigger area until the start of next monitoring
a=10 to 500 ; [Unit: ms]
Set the time interval until the start of monitoring after the
trigger area monitoring is enabled.
a=5 to 20 ; [Unit: s]
Set the endian when PLCMODE=1 is set
a=0 Little endian(*)
a=1Big endian
Status transmission (Settings for PLC link mode)
87
(*)=Default