Panasonic LP-ABR11 Setup And Operation Manual page 38

Lp-abr10 series code reader
Table of Contents

Advertisement

Force-quit running auto-tuning
*cancel
Auto-tuning takes a lot of time. This command is used for canceling an
auto-tuning. Code Reader force-quits the auto-tuning.
Check the condition of LP-ABR
*?state
This command is used for checking the condition of your Code Reader.
The answers from Code Reader are as follows.
Condition
Reading standby
Auto-tuning
Waiting data save
Reading
Save Tuning Result (Table Mode)
*save
This command is used for saving a result of auto-tuning to the table mode.
When Code Reader receives this command within 40 seconds after the
completion of auto-tuning, the result of the tuning is saved to the table mode.
If no command is received, Code Reader times out and returns to reading
standby state.
Save Tuning Result (Manual Mode)
*save2
This command is used for saving a result of auto-tuning to the manual mode.
When Code Reader receives this command within 40 seconds after the
completion of auto-tuning, the result of the tuning is saved to the manual
mode. If no command is received, Code Reader times out and returns to
reading standby state.
Refer to saved result of tuning
?ddmtbl
This command is used for saving a result of auto-tuning to the manual
mode.
Answer
STANDBY[CR]
RECEIVED[CR]
SAVEWAIT[CR]
(No answer)
38