7.3

Symbol Reading (Operating mode, adjustment and diagnostic)

Term
Command
Reading
g
BR=a
DECODELIM=
a
Operation
SYNCMODE=
Mode
a
VOUT=a
TOTALLIM=a
Continuous
continue
Reading Mode
stop
contintvl=a
?contintvl
Test Mode
TEST=a
TMN=a
I/O Test
IOTEST=a,b
Reading
?total
Statistics
clrtotal
Display
?dect
Reading Time
clrdect
Warning
CHKBCR=a
Information
(,b)
Symbology
SYMBOLTX=a
Information
Decoding time
DTTX=a (,b)
Description
Start reading (SYNC ON) † The default setting is valid only RS-232C
interface
No read message a=0 None, a=1 "BR"(*), a=2 "ERROR", a=3 "?"
Set the time limit for decoding process
a=100 to 10000 [ms], 10[ms] step
a=0; Normal Mode
a=1; Reading Timeout Mode (*)
a=2; External Trigger Mode
Output timing a=0,1 (0: After decoding (*), 1: After SYNC off)
Decode timeout、a=XXXX [ms],10[ms]step,
Default: 3000[ms] (*)
Enable Continuous Reading Mode
Stop Continuous Reading Mode (back to Normal Mode) (*)
Set a time interval of reading
a= 0 to 9
[Unit: s]
a=10 to 999 [Unit: ms]
Check the value of contintvl
a=0; Normal Mode (*), a=1; Test Mode
Number of reading times in Test Mode a=10 (*) -1000 (10 steps)
Turn on I/O output during specified time
a=D1 ;DOUT1 port
D2 ;DOUT2 port
D3 ;DOUT3 port
b=0 OFF(*)
(Output OFF in any port)
1 to 1000 Turn on during specified time [ms]、
-1 Remain ON
Check number of times for SYNC, Good Read, No Read from Power-on
reset
Clear the value of number of times
Check decoding time of Good Read, No Read (Minimum, maximum
and average)
Clear the value of decoding time
a=0; Disable addition for RS232C (*)
RS232C
b=0; Disable addition for LAN (*)
Omit (,b):
Set RS-232C and LAN in the same way (=a)
a=0; Disable addition of SYMBOLTX (*)
a=1; Enable addition of SYMBOLTX
a=0; Disable addition of DTTX for RS-232C(*)
a=1; Enable addition of DTTX for RS-232C
b=0; Disable addition of DTTX for LAN(*)
b=1; Enable addition of DTTX for LAN
Omit (,b):
Set RS-232C and LAN in the same way (=a)
80
(*)=Default
a=1000 [ms](*)
a=1 [s] (*)
a=1; Enable addition for
b=1; Enable addition for LAN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp-abr12Lp-abr10-c5Lp-abr10-l5