E152
PF locked in job mode
E153
Not Ok to select
new job
E154
Remote job running
E155
Remote job aborted
E156
Job members lost
E157
Job reference lost
E158
Invalid Job ID
E159
No Pset In Selected Job
E160
Job select source not
valid
E161
Line Control Alert 1
E162
Line Control Alert 2
E166
Job aborted
E167
Max coherent NOK
tightenings reached
E175
Confi guration will be
erased at next reboot
E176
IPM memory needed
-
This error appears when in a forced
cell job an attempt is made to tighten
with a controller which is not currently
active or when a controller has perfor-
med all tightenings.
-
A job is currently running, it is not pos-
sible to select a new job until the fi rst
is fi nished in some way (completed
or aborted). This message is also
displayed if a job is selected on a job
member.
-
When running a Cell Job, this is displayed
by the job members when a cell job is
selected on the job master.
-
When running a Cell Job, This is displayed
by the job members when a cell job is
aborted.
-
When running a Cell Job, this is displayed
by the master when it has lost contact
with one of its job members.
-
When running a Cell Job, this is displayed
by the job members when they have lost
contact with their Job Master.
-
When the selected job does not exist.
-
When the selected job does not contain
any Pset.
-
Attempt to select a Job with the wrong
input source.
-
The line control has been activated,
and the fi rst control alert limit has been
reached.
-
The line control has been activated, and
the second control alert limit has been
reached.
A running job has been aborted
The pre-set no. of successive NOK
tightenings was reached. Unlock via
digital input.
Due to changed memory setup. Valid
for both PF and RBU.
Not possible to confi gure without IPM
memory
28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Power Focus 4000 Graph and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Power focus 4000 compactPf 4000 compactPf 4000 graph

Table of Contents

Save PDF