Atlas Copco EBL Drive Configuration Manual

Atlas Copco EBL Drive Configuration Manual

Drives and controllers

Advertisement

EBL Drives and Controllers
Printed Matter No. 9836 5849 01
Publication Date 2019-08-26
Valid for Version No. 1
EBL Drive
EBL Drive Plus
EBL RE-Drive
EBL RE-Module
EBL LS controller
EBL ST controller
Read all safety warnings and instructions
Failure to follow the safety warnings and instructions may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference
8431 0170 70
8431 0170 85
8431 0170 75
8431 0170 76
8431 0170 81
8431 0170 80
WARNING
Configuration Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EBL Drive and is the answer not in the manual?

Questions and answers

Summary of Contents for Atlas Copco EBL Drive

  • Page 1 Printed Matter No. 9836 5849 01 Publication Date 2019-08-26 Valid for Version No. 1 Configuration Manual EBL Drive 8431 0170 70 EBL Drive Plus 8431 0170 85 EBL RE-Drive 8431 0170 75 EBL RE-Module 8431 0170 76 EBL LS controller...
  • Page 2: Table Of Contents

    Output Signals (COMP, VALVE, BZ, ER BZ) ........ 15 Settings...................... 15 Enter settings.................. 16 Main setting table ................ 16 System setting tables ................ 17 Stand alone circuit .................. 18 Quick start example .................. 18 Functions ...................... 19 Troubleshooting .................... 19 Timing chart .................... 20 © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 3: Liability

    Ensure that the joint conditions have not changed due to events of influence. ■ Be done after initial installation, maintenance or repair of the equipment. ■ Occur at least once per shift or at another suitable frequency. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 4: System Description

    System description EBL Drives and Controllers System description Connection examples © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 5: Ebl Compatibility Matrix

    0170 15 EBL20 8431 0170 16 EBL20- 8431 0170 20 EBL21- 8431 1500 0170 43 EBL25 8431 0170 23 EBL25- 8431 0170 28 EBL35 8431 0170 33 EBL35- 8431 0170 38 © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 6 0170 39 EBL25- 8431 1500 0170 25 EBL45 8431 0170 40 EBL55 8431 0170 44 EBL25- 8431 1500- 0170 22 EBL45- 8431 0170 42 EBL55- 8431 0170 45 EBL03- 843101 7003 © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 7: Free Speed Data

    8431 0170 43 1000 1500 EBL25 8431 0170 23 EBL25-SS 8431 0170 28 EBL35 8431 0170 33 EBL35-SS 8431 0170 38 EBL-12-ST 8431017014 EBL-25-ST 8431017024 EBL-35-ST 8431017037 EBL03-RE 8431 0170 55 © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 8 8431 0170 42 EBL55-RE 8431 0170 45 EBL03-LS 8431017003 EBL03-Q-LS 8431017005 EBL03-LS-RE 8431017056 EBL03-Q-LS-RE 8431017009 EBL12-LS 8431017012 EBL12-LS-RE 8431017010 EBL25-HD 8431017123 EBL25-HD-SS 8431017128 EBL35-HD 8431017133 EBL35-HD-SS 8431017138 EBL45-HD 8431017140 EBL55-HD 8431017144 © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 9: Ebl Drive And Ebl Drive Plus

    Select the rundown speed (SPEED). ■ HI = 100% speed ■ LOW = 70% speed Use the torque adjustment key to select the tightening torque. The key is included in the EBL tool. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 10: Ebl St Controller

    A LOW rotation setting with maximum, or just below maximum torque could result in a poor result. Use HI-setting when utilizing a high torque setting if possible. The maximum speed depends on the setting of either EBL Drive or EBL Drive Plus. If the setting is LOW, the maximum is 70%.
  • Page 11 EBL Drives and Controllers EBL ST Controller A: EBL25-ST; EBL35-ST B: EBL12-ST © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 12: Ebl Ls Controller

    SPEED VR. The LS function is only valid for Forward Rotation. The speed of Reverse Rotation is the same as the setting of EBL Drive, EBL Drive Plus or EBL RE-Drive. Connectors/Display Connector to be plugged into RE cable from EBL-RE-LS tools.
  • Page 13: Ebl Re-Drive And Ebl Re Module

    Change Function Mode will cause a buzzer to sound, exit the Change Function Mode. Function Switch 2 (x10) Numbers increase in increments of 1 as the button is pressed. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 14: Rear Panel

    VALVE signal and releases the work piece held by an external device. Performs the same function as the Reset Switch on the front panel. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 15: Input Signals (Set, Reset)

    Settings The function settings of the unit is performed by using the buttons F1, F2 and F3. Each button has a corre- sponding seven-segment LED display. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 16: Enter Settings

    Tool Disable Timer 2 Set a pause timer after 0.0 - 3.9 s the end of the batch (end of the VALVE-signal). When time is up, the screwdriver returns to nor- mal operation. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 17: System Setting Tables

    Screwdriver operation set to OFF: SET-signal determines when screwdriver operation is allowed. ■ Screwdriver operation set to ON: Screwdriver operation is always allowed. ■ Tightening buzzer: Buzzer sounds when the tool makes an OK tightening. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 18: Stand Alone Circuit

    ) Setting range: 0.1 to 1.0 s. Set minimum time span for loosening a screw. This will enable the counter to handling loosening of screw. Press F3 for 0.1 s. Ex: For 0,5 s, ( 0,5), press F3 five times. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 19: Functions

    Confirm that the fuse has not failed. If the fuse has failed, replace it with a spare. Then turn on the main power switch again and confirm that the main power switch LED lights up. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 20: Timing Chart

    The screwdriver will not function. Make sure the unit is not set in factory default mode (system setting mode 00). Timing chart Blue arrows shows the relationship between the signals. © Atlas Copco Industrial Technique AB - 9836 5849 01...
  • Page 24 Original instructions Atlas Copco Industrial © Copyright 2019, Atlas Copco Industrial Technique AB. All rights reserved. Any Technique AB unauthorized use or copying of the contents or part thereof is prohibited. This SE-10523 STOCKHOLM applies in particular to trademarks, model denominations, part numbers and drawings.

Table of Contents