KNX
Planning and application
4.4.5

Tabular overview of bus voltage recovery, download and ETS reset

Device general
Behavior
Transmission and
switching delay
Communication object
"In operation"
Output: fan
Behavior
Status byte
Status messages
Output control
Start-up behavior
Enable/disable commu-
nication object "Run-on"
Run-on behavior
Forced operation
Automatic ON/OFF
Control value monitoring
in automatic mode
Limitations
Output: Switch actuator
Reaction
Status messages
Output control
Staircase lighting time
Disable function Time
Permanent On
94 2CDC508116D0203 | FCL/S x.6.1.1
On bus voltage recovery
Yes (can be parameterized)
Sends after send delay.
Cycle time commences after
initialization.
On bus voltage recovery
Error bit is reset and set
again if necessary
Sent if send reaction is set to
"Only after changing" or
"After a change or request".
Can be parameterized sepa-
rately for bus voltage failure
and recovery
Unchanged
Unchanged
Stopping time restarts at
current speed.
Unchanged
Unchanged
Monitoring time is restarted.
Control value fault is reset.
Unchanged
On bus voltage recovery
Sent if send reaction is set to
"Only after changing" or
"after a change or request".
Can be parameterized sepa-
rately for bus voltage failure
and recovery
Continues
Unchanged
Unchanged
Download
None
Cycle time commences after
initialization.
After download
Error bit is reset and set
again if necessary
Sent if send reaction is set to
"Only after changing" or
"After a change or request".
Unchanged
Unchanged
Unchanged
Stopping time restarts at
current speed.
Unchanged
Unchanged
Monitoring time is restarted.
Control value fault is reset.
Unchanged
After download
Sent if send reaction is set to
"Only after changing" or
"After a change or request".
Unchanged
Continues
Can be parameterized
Unchanged
After ETS reset, full down-
load and application up-
date
None
Cycle time commences after
initialization.
After ETS reset, full down-
load and application up-
date
Error bit is reset and set
again if necessary
Sent if send reaction is set to
"Only after changing" or
"After a change or request".
Off
Canceled
Enabled
Canceled
Canceled
On
Monitoring time is restarted.
Control value fault is reset.
Inactive
After ETS reset, full down-
load and application up-
date
Sent if send reaction is set to
"Only after changing" or
"After a change or request".
Off
Not active
Not active
Not active