Behaviour With Bus Voltage Failure, Recovery, Download And Ets Reset - ABB ES/S 4.1.2.1 User's Product Manual

I-bus knx electronic switch actuator
Table of Contents

Advertisement

ABB i-bus KNX
4.5
Behaviour with
bus voltage failure,
recovery, download
and ETS reset
Behaviour
At bus voltage failure
Output control
Parameterized default
position is set with bus
voltage failure
Monitoring control
Monitoring inactive
value
Forced operation
Forced operation is
ended. Parameterized
default position is set with
bus voltage failure
Block
Blocking is ended. Pa-
rameterized default posi-
tion is set with bus voltage
failure
Valve purge
Valve purge is ended.
Parameterized default
position is set with bus
voltage failure
Manual operation
Manual operation is
ended. Parameterized
default position is set with
bus voltage failure
Power saving mode
All LEDs are off
(LEDs off in KNX
mode)
© 2010 ABB STOTZ-KONTAKT GmbH
Planning and application
At bus voltage recovery
Parameterized default
position is set with bus
voltage failure
Monitoring time will be
restarted
Active, provided that
forced operation was also
active before bus voltage
failure
Inactive, communication
object value is reset
Valve purge is inactive.
Communication object
Status valve purge = 0.
Injection cycle time re-
starts (provided that
automatic valve purging is
activated)
Inactive
Power saving mode is
activated after a param-
eterized time
At download (DL)
At ETS reset
Control with the communi-
Off
cation object value before
download
Monitoring time will be
Monitoring time will be
restarted. Communication
restarted. Communication
object value unchanged
object value is reset
Inactive, communication
Inactive, communication
object value is reset
object value is reset
Inactive, communication
Inactive, communication
object value is reset
object value is reset
Valve purge is inactive.
Valve purge is inactive.
Communication object
Communication object
Status valve purge = 0.
Status valve purge = 0.
Injection cycle time re-
Injection cycle time re-
starts (provided that
starts (provided that
automatic valve purging is
automatic valve purging is
activated)
activated)
Inactive
Inactive
Power saving mode is
Power saving mode is
activated after a param-
activated after a param-
eterized time
eterized time
51