Satellite Siren Service Mode; Add/Delete User Code/Rf Keyfob; Change Domestic Telephone Numbers; Turn Outputs On/Off - Bosch CC488 Quick Reference Manual

Solution ultima 880
Hide thumbs Also See for CC488:
Table of Contents

Advertisement

CC488 | Quick Reference Guide | 1.0 Overview
1.12

Satellite Siren Service Mode

Enter the four character Installer Code, followed
by [5] and the [#] key (for example, [1 2 3 4 5 #]).
1.13
Telephone Monitor Mode (Toggle
On/Off)
1. Enter the four character Installer Code,
followed by [6] and the [#] key (for example,
[1 2 3 4 6 #]).
2. Press and hold the [9] key until two beeps are
heard to send a test report.
Table 6:

Telephone Monitor Mode

Zone LED
Dialling Event
1
Telephone Line Seized
2
Dialling Telephone Number
3
Handshake Received
4
Data Being Sent
5
Kiss-Off Received
None
Released Telephone Line
1.14
Add/Delete User Code/RF
Keyfob
1.14.1

Add A User Code

1. Enter the four character Master Code,
followed by [1] and the [#] key (for example,
[2 5 8 0 1 #]).
2. Enter the User Number (1 to 16) you want to
add/change, followed by the [#] key.
3. Enter the new code, followed by the [#] key.
1.14.2

Add RF Keyfob

1. Enter the four character Master Code,
followed by [1] and the [#] key (for example,
[2 5 8 0 1 #]).
2. Enter the User Number (9 to 16) you want to
add, followed by the [#] key.
3. Enter the 9-digit RF keyfob ID number,
followed by the [#] key.
1.14.3

Delete a User Code/RF Keyfob

1. Enter the four character Master Code,
followed by [1] and the [#] key (for example,
[2 5 8 0 1 #]).
2. Enter the User Number (1 to 16) you want to
delete, followed by the [#] key.
3. Press the [*] key to delete the User Code.
Bosch Security Systems | 6/04 | 4998152446B
1.15
Change Domestic Telephone
Numbers
1. Enter the four character Installer Code or
Master Code, followed by [2] and the [#] key
(for example, [1 2 3 4 2 #]).
2. Enter the digits for the telephone number.
3. If there is more than one telephone number,
press the [*] key, followed by the [4] key
(inserts break between phone numbers) and
repeat Step 2, or press the [#] key to exit.
1.16

Turn Outputs On/Off

1. Enter the four character Master Code,
followed by [5] and the [#] key (for example,
[2 5 8 0 5 #]).
2. Enter the Output Number (1 to 3) you want to
toggle on or off.
3. Press the [#] key to toggle on or the [*] key to
toggle off.
4. Press the [#] key to exit.
1.17

Setting Date and Time

1. Enter the four character Master Code,
followed by [6] and the [#] key (for example,
[2 5 8 0 6 #]).
2. Enter the day (DD), month (MM), and year
(YY) followed by the hour (HH) and minute
(MM).
3. Press the [#] key to exit.
1.18
Day Alarm – Toggle On/Off
Press and hold the [4] key until two beeps are
heard. Day alarm toggles on or off.
1.19
STAY Mode 2 Zones – Program
1. Enter the four character Installer Code or
Master Code, followed by [4] and the [#] key
(for example, [1 2 3 4 4 #]).
2. Enter the Zone Number you want the system
to automatically isolate, followed by the [*]
key.
Repeat if more than one zone must be
automatically isolated when armed in STAY
Mode 2.
3. Press the [#] key to exit.
EN | 9