AudioCodes Mediant 1000 User Manual page 173

Voip media gateways, sip protocol
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

SIP User's Manual
MOS value changes by 0.1 (hysteresis) to 3.3 or 3.5, the device sends a report to the
SEM indicating this change. If the value changes to 3.3, it sends a yellow state (i.e.,
medium quality); if the value changes to 3.5, it sends a green state.
4.
Configure the parameters as required. See the table below for a description of each
parameter.
5.
Click Submit to apply your settings.
Table 12-4: Quality of Experience for Media Realm Parameter Descriptions
Parameter
Index
[QOERules_RuleIndex]
Monitored Param
[QOERules_MonitoredParam]
Profile
[QOERules_Profile]
Green Yellow Threshold
[QOERules_GreenYellowThreshold]
Green Yellow Hystersis
[QOERules_GreenYellowHystersis]
Yellow Red Threshold
[QOERules_YellowRedThreshold]
Yellow Red Hystersis
[QOERules_YellowRedHystersis]
Version 6.4
Defines the table index entry. Up to four entries can be
configured per Media Realm.
Defines the parameter to monitor and report.
Mos (default)
Delay
PacketLoss
Jitter
Defines the pre-configured threshold profile to use.
No Profile = No profile is used and you need to define the
thresholds in the parameters described below.
Low Sensitivity = Automatically sets the thresholds to low
sensitivity values. Therefore, reporting is done only if
changes in parameters' values is significant.
Default Sensitivity = Automatically sets the thresholds to a
medium sensitivity.
High Sensitivity = Automatically sets the thresholds to
high sensitivity values. Therefore, reporting is done for
small fluctuations in parameters' values.
Defines the parameter threshold values between green
(good quality) and yellow (medium quality) states.
Defines the hysteresis (fluctuation) for the green-yellow
threshold. When the threshold is exceeded by this hysteresis
value, the device sends a report to the SEM indicating this
change.
Defines the parameter threshold values between yellow
(medium quality) and red (poor quality). When this threshold
is exceeded, the device sends a report to the SEM indicating
this change.
Defines the hysteresis (fluctuation) for the yellow-red
threshold. When the threshold is exceeded by this hystersis
value, the device sends a report to the SEM indicating this
change.
173
Description
12. Media
March 2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediant 600