4-1 Installation Conditions

4-1 Installation Conditions

Space Conditions around Servo Drives

Space Conditions around Equipment
 Install Servo Drives according to the dimensions shown in the following illustration to ensure
proper dispersion of heat from inside the drive and convection inside the panel. If the drives are
installed side by side, install a fan for air circulation to prevent uneven temperatures inside the
panel.
4
 W must be 50 mm or more if 7.5-kW or 15-kW Servo Drives are installed.
 Servo Drives of 100 V or 200 V with a capacity of 750 W max. can be installed side by side with
a 1-mm clearance (W in above illustration). For ambient temperature requirements, refer to
Environment Operating Conditions below.
 If the mounting surface of the Servo Drive is coated, remove the coating to allow electrical
conduction. If you make your own mounting bracket, we recommend that you apply electrically
conductive plating.
Mounting Direction
 Mount the Servo Drive perpendicular on the panel so that the model number reads normally.
Environment Operating Conditions
 The environment in which drives are operated must meet the following conditions. Drives may
malfunction if operated under any other conditions.
 For Servo Drives of 100 V or 200 V with a capacity of 750 W max., the specifications for operating
ambient temperature depend on the Servo Drive (A, B, and C) when the clearance between Servo
Drives is 1 mm.
4-1
Fan
Servo
Servo
Drive
Drive
A
B
W
40 mm or more
W = 10 mm or more
Operating ambient temperature: 0 to +55°C (Take into account temperature rises in the
following individual drives themselves.)
Operating humidity: 85% max. (with no condensation)
Operating atmosphere: No corrosive gases.
Altitude: 1,000 m max.
Servo Drive A: 0 to 50 °C
Servo Drive B: 0 to 40 °C
Servo Drive C: 0 to 45 °C
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
100 mm min.
Fan
Servo
Drive
C
W
100 mm min.
Air
Side
of
Servo
Drive
Air

Hide quick links: