O p e r a t i o n
v i a
W i n d o w s
POTS, VoIP
ISDN
P A G E 6 8
P C
S o f t w a r e
5.6.4.2.7

Audio Interface

MAGIC TH6 supports analogue as well as digital AES/EBU Audio interfaces.
If the digital Audio inputs are used, a Sample Rate Converter is available so
that external adjustments are not required if there are different digital sources
and drains.
FIG. 44
Mode
• The operating mode analogue or digital can be set separately for the Au-
dio Input and the Audio Output.
AES/EBU Interface
• If the digital output is selected, the configuration for the AES/EBU Inter-
face is displayed. Under Clock Source of digital output you can select
the following options:
– Internal: The AES/EBU output clock is derived from the internal sys-
tem clock.
– External: The AES/EBU output clock is derived by the external clock
connected via the AES/EBU/CLK adapter cable. The clock rate of the
connected clock must be 48-kHz.
– Recovered: The AES/EBU output clock is derived from the digital in-
put signal of the interface. This configuration is usually to be selected if
you use the digital input of the system. In this way a synchronous func-
tioning of the transmission chain is ensured
NOTE
If you are using MAGIC TH6 ISDN in the ISDN operating mode, the clock of
the AES/EBU output is derived from the ISDN clock. Therefore, if the ISDN
Mode is selected, this settings will not be displayed.
The AES/EBU input always works with recovered clock, therefore only a
configuration of the output is required.