A2.4
Control Interfaces
A2.4.1
LAN interface
Please see A2.1.3, Page 115.
A2.4.2
RS232/Keypad Interface
The RS232/Keypad interfaces 1 and 2 are developed for the connection of
MAGIC TH6 Keypads to operate the MAGIC TH6 Telephone Hybrid. Both in-
terfaces have the same functionality and can be used at the same time to op-
erate the MAGIC TH6. For each interface a separate 9-pin Sub-D socket is
available. The pin assignments of the two 9-pin Sub-D sockets are shown in
TAB. 12 and TAB. 12.
TAB. 12
1
5
Socket: SUB-D (9 pin)
6
9
Pin
1
2
3
4
5
6
7
8
9
TAB. 13
Socket: SUB-D (9 pin)
Pin
1
2
3
4
5
6
7
8
9
PIN ASSIGNMENT: RS232/KEYPAD 1 INTERFACES
Function
nc
TxD1
RxD1
nc
GND
nc
nc
nc
nc
PIN ASSIGNMENT: RS232/KEYPAD 2 INTERFACE
Function
nc
TxD2
RxD2
nc
GND
nc
nc
nc
nc
I n t e r f a c e s
P A G E 11 9