Load Factory settings
settings. Presets are not deleted.
NOTE
If the Preset has changed, you are asked if you want to
you leave the Preset menu. Via the
the system. This Preset is loaded automatically by the system after the unit is
connected with the power supply.
4.1.4

RS232 Interfaces

MAGIC TH6 provides two RS232 interfaces:
RS232 interface 1 is always configured for the connection of an external key-
pad with the following parameters 9,600 bit per second, 8 data bits, no parity
and cannot be changed.
RS232 interface 2 can be configured for the connection of an external keypad
or a PC.
– To configure the RS232 interface 2 press the
Settings
– Go to the
select the required baudrate and parity.
NOTE
If you configure the RS232/Keypad 2 interface for the use with a PC, the PC
control via the LAN interface will be deactivated.
F r o n t
D i s p l a y
: This function resets the system into the standard
yes
.
General
submenu and select
a n d
K e y p a d
O p e r a t i o n
save settings
softkey the configuration is stored in
Menu
softkey and select
RS232/KEYPAD 2 ( PC )
. Now you can