I
NSTALLING THE
Chapter 4
Installation

Speed Control

Double/reinforced insolation
boundary provided by users
potentiometer and run switch
*
'Run' connects to Common to 'Enable' Speed Control.

Current Control

* Additional line fuse recommended for applications where live
'Run' connected to +10V to 'Enable' Current Control and
'Override' Stall detection.
506/507/508 - HA389427
Figure 4.1 Wiring Diagram Speed Control
Fuse
Fuse
MAINS
*
FILTER
10K
RUN
Additional line fuse recommended for applications where live
connections are made rather than live and netral.
Figure 4.2 Wiring Diagram Current Control
Fuse
Fuse
*
10K
10K
SPEED SETPOINT
Double/reinforced insolation
boundary provided by users
potentiometers and run switch
Optional Speed Setpoint potentiometer to limit overspeed, connect
setpoint direct to +10V if not required.
connections are made rather than live and netrual
www.comoso.com
Installing the 506/507/508
506/507/508
L1
F +
F -
L2/N
A -
GRD
A +
GRD
6
I LIMIT
5
+ 10 V
4
SETPOINT
3
RUN
2
COMMON
TACHO GENERATOR
1
L1
MAINS
L2/N
FILTER
GRD
6
I LIMIT
+ 10 V
5
SETPOINT
4
RUN
3
RUN
2
COMMON
1
TACHO GENERATOR
4-1
FF
F
A
AA
T6
neutral
FF
F +
F
F -
A
A -
AA
A +
GRD
T6
neutral