Installation

Connector C1
Connector kit
Housing
Casing
Plane sealing, 42 p
Pin types*
Cables
Seals
Plugs (empty pos.)
IQAN crimping tool ref-
erences
IQAN tool kit
Connector pin assignments
+BAT
-BAT
+VREF
-VREF
XS2
PORT 0
Logical
Pin
(I)nput or
Symbol
No.
(O)utput
+BAT
28
-
-BAT
15
-
+VREF
42
-
-VREF
29
-
ADDR-H
1
-
ADDR-L
14
-
CAN-H
26
-
27
-
CAN-L
40
-
41
-
Instruction book, IQAN- XS2
Parker no. 5031063
Amp no. 1-963226-1
Amp no. 0-965643-1
installed in module
Amp no. 963711-2 (MT)
0,75-1,0 mm² (MT)
Amp no. 963530-1 (MT)
Amp no. 963531-1 (MT)
Blue handle, pos. A
use blue extraction tool
Parker no. 5031061
ADDR-H
ADDR-L
CAN-H
CAN-L
PORT 1
PORT 2
Function description
and/or Signal name(s)
Power supply, positive.
Power supply, negative ground
Voltage reference for external sensors. Sourcing +5V.
Voltage reference for external sensors. Return (0V).
High side to address tag. Sourcing +5V.
Low side to address tag. Return (0V).
CAN high voltage bus line, will be HIGH in dominant state.
CAN low voltage bus line, will be LOW in dominant state.
6
Installation
42
28
14
*= The connector contains two types
of terminals; MT (Micro Timer) and
JPT (Junior Power Timer).
Amp no. 929938-1 (JPT)
1,5-2,5 mm² (JPT)
Amp no. 828905-1 (JPT)
Amp no. 828922 (JPT)
Red handle, pos. B
use yellow extraction tool
29
15
1
9